MGP12 High-Stiffness Structural Pine Framing 90 x 35 & 90 x 45 mm (Untreated & H2)

IPP eligible4 specificationsAS/NZS 1748.1AS 1720.1AS 1684.2

MGP12 is a high-stiffness machine-graded structural radiata pine delivering 12,700 MPa average modulus of elasticity and substantially higher characteristic bending strength than MGP10. Stocked in 90 x 35 mm and 90 x 45 mm across 2.4 m to 6.0 m lengths in both untreated and TAN T H2 termite-treated variants, MGP12 handles high wind loads, tall wall studs, and truss chords without increasing frame depth.

Supply Nation Certified. First Nations owned. Price on quote. Fast response times.

Key system details

  • Higher characteristic bending strength (28 MPa vs 17 MPa for MGP10) and 12,700 MPa stiffness modulus under AS/NZS 1748.
  • Stocked in 90 x 35 mm and 90 x 45 mm across 2.4 m to 6.0 m lengths in both untreated and TAN T H2 termite-treated finishes.
  • Allows builders to maintain a standard 90 mm wall cavity in tall walls, upper-storey load-bearing frames, and cyclonic C1 to C3 wind zones.
  • Preferred solid-pine chord and web grade for prefabricated roof trusses carrying tiled roofs or long clear spans.
  • Supplied with mill grade verification stamps and H2 treatment certificates to streamline structural frame inspections.

Compliance and applications

Standards and ratings

  • AS/NZS 1748.1 Timber solid stress-graded for structural purposes (MGP12)
  • AS 1720.1 Timber structures characteristic strength and stiffness design tables
  • AS 1684.2 & AS 1684.3 Residential timber-framed construction (non-cyclonic and cyclonic wind zones)
  • AS/NZS 1604.1 Hazard Class H2 preservative treatment on TAN T MGP12 H2 stock

Common applications

  • Tall single-storey and two-storey lower-level load-bearing wall studs
  • Prefabricated roof truss top chords, bottom chords, and high-load web members
  • High wind-speed coastal N3, N4, and cyclonic C1 to C3 wall framing
  • Jamb studs beside wide sliding doors, corner windows, and double garages
  • Compact roof rafters, strutting beams, and high-stiffness ceiling battens

Every order counts toward Commonwealth IPP and state Indigenous procurement targets. A trade account is optional. You do not need one to request a quote or to buy from Birak; credit trade accounts are available for businesses that want to buy on credit.

MGP12 Structural Pine specifications

4 specifications

All items are priced on quote for your project quantities and delivery site. Upload drawings or a bill of quantities for a full takeoff.

MGP12 Structural Pine specifications
SpecificationDimensionsLengthGrade / SpecQuote
Untreated MGP12 Structural Pine
MGP12 Untreated Structural Radiata Pine 90 x 35 mm 2.4 m to 6.0 m90 x 35 mm2.4 m to 6.0 mMGP12 High-Stiffness, UntreatedQuote
MGP12 Untreated Structural Radiata Pine 90 x 45 mm 2.4 m to 6.0 m90 x 45 mm2.4 m to 6.0 mMGP12 High-Stiffness, UntreatedQuote
TAN T H2 Termite-Treated MGP12
TAN T MGP12 H2 Termite-Treated Structural Pine 90 x 35 mm 2.4 m to 6.0 m90 x 35 mm2.4 m to 6.0 mMGP12 High-Stiffness, TAN T H2 Termite TreatedQuote
TAN T MGP12 H2 Termite-Treated Structural Pine 90 x 45 mm 2.4 m to 6.0 m90 x 45 mm2.4 m to 6.0 mMGP12 High-Stiffness, TAN T H2 Termite TreatedQuote

Frequently asked questions

When does an engineer specify MGP12 instead of MGP10 in a 90 mm wall frame?
Engineers step up from MGP10 to MGP12 whenever stud heights exceed 2.7 m, wind classifications rise to N3, N4, or cyclonic C-ratings, or point loads from upper floors and heavy roof trusses exceed MGP10 axial buckling capacity while the wall cavity must remain 90 mm deep.
Should I order untreated MGP12 or TAN T H2 MGP12 for my project?
Choose TAN T H2 MGP12 across mainland Australian termite-risk areas where treated framing forms part of the NCC termite management system. Untreated MGP12 suits Tasmania, certified low-risk zones, or commercial frames protected by an independent physical or chemical barrier specified by the building surveyor.
Can MGP12 90 x 45 mm replace LVL jamb studs beside standard window openings?
For many standard residential window and door jambs, single or doubled 90 x 45 mm MGP12 studs satisfy AS 1684 wind-load tables economically without moving to engineered LVL. For very wide bifold doors, multi-storey point loads, or severe wind exposures, pair MGP12 wall frames with Birak's E13.2 or Spec Frame LVL.
Can truss plants and multi-unit builders consolidate MGP12 and LVL on one Birak IPP order?
Yes. Frame and truss fabricators servicing Commonwealth, Defence, or state social housing contracts can bundle MGP12 chords, MGP10 wall frames, and Spec Chord LVL on a single Supply Nation Certified purchase order with consolidated IPP documentation.

More MGP Pine Framing systems

Compare related systems in our MGP Pine Framing range, or return to the full Structural Timber & Framing department.

Need a quote on MGP12 Structural Pine?

Send your schedule, product codes, or plans. Our team replies fast with trade pricing, Australia-wide freight options, and Supply Nation Certified IPP reporting.

CallGet a quote

Set your delivery site

We deliver Australia-wide. Your site goes with your quote request, and freight is quoted with your order.